INSTALLATION PLANNING
0 A qualified technician must complete the installation of this
built-in appliance. Proper installation is the responsibility of
the customer.
0 Carefully check the installation location. The oven should be
placed for convenient access. Make certain that electrical
power can be provided in the selected location.
Plan the installation so that all minimum clearances are
met or exceeded. Dimensions shown provide minimum
clearances, unless otherwise noted. Be certain that proper
clearance is provided for the oven door when it is in the open
position.
0 The specified minimum cabinet depth and width must be
provided. The cabinet depth and width must completely
enclose the recessed portion of the oven.
Cabinet cutout dimensions must be used as indicated. All
contact surfaces between the appliance and the cabinet must
be solid and level. The oven support platform must be flush
with the bottom edge of the cabinet cutout.
0 Make certain that you have everything necessary to ensure a
proper installation before proceeding.
NOTES:
1. Minimum Cutout Depth:
Model IOWO24 - 20" (508mm)
All other models - 23 3/8" (594mm)
2. The IOWO24 and EWO36 models cannot be stacked.
3. The IOWO24 warming oven is not approved for
installation under a wall oven.
in
( mm)
3_
AL
D
J!_
t
in
(6mm)
I
6
Dacor
single oven
Warming Oven
I
I
Warming Oven
oe ic
Stacked Installation with Wall Oven
ac
electrical
outlets
Model
IOWO24
IWO24
EWO24
EW27
EWO27
IWO27
MW27
MWO27
PW27
EW30
EWO30
MW30
MWO30
PW30
PWO30
EWO36
"A" Cutout
Width
22 9/16" (573mm)
22 1/2" (572mm)
25 1/2" (648mm)
34 3/8" (873mm)
"B" Min. Width
to Adjacent
Doors/Drawers
N/A*
24 1/4" (616mm)
27 1/4" (692mm)
N/A*
27 1/4" (692mm)
30 1/4" (768mm)
"C" Cutout
Height
12 1/8" (308mm)
9 1/8" (232mm)
"D" Min. Gap
Between Cutouts
N/A*
1 1/16" (27mm)
N/A*
36 1/4" (921mm
* Depends on size of cabinet face installed.
1 1/16" (27mm)
3" (76mm)
Table 1: Cutouts Dimensions
4 _acar