Vista de página 9
RE-INSTALLING THE
1.
2.
3.
4.
5.
6.
DRAWER
Pull the drawer slides all the way out of the drawer
opening.
Gently lower the drawer between the extended slides
until the drawer is suspended by the slide rails.
Slide the back of the drawer mounting brackets under
the drawer mounting clips on the slides.
Push the side of the drawer down onto its locking tab,
until the tab locks into place.
Repeat the same process on the opposite side.
Gently open and close the drawer to make sure that it
is properly installed.
STEP 3: Slide mounting
bracket under clip on
slide
Clip on slide
STEP 4: Push front of
drawer down until tabs
lock into place
f
Slide
INSTALLATION CHECKLIST
[]
[]
[]
Has a properly grounded, dedicated, three prong
electrical outlet been installed for the appliance by a
licensed electrician? See page 6.
Has the mounting platform been installed according to
the instructions on page 6?
Has the chassis been properly fastened to the
mounting platform and sides of the cabinet?
See page 7.
Has the drawer been properly installed?
Has proper operation been verified?
Have any problems been noted on the warranty card
or during the on-line warranty activation? Has the
warranty been activated on-line or the warranty card
filled out completely and mailed?
VERIFYING OPERATION
1. Before connecting the power plug, turn the
TEMPERATURE and TIMER knobs are set to the OFF
position.
2. Plug the power cord into the electrical outlet.
3. Operate the warming drawer as outlined in the use and
care manual that accompanied this product.